aHR0cDovL2ZyZWVzaGlwLmNvLmty Item specifics
- Model Number:
- 0.1 seconds timer
- Brand Name:
- Relay
- Usage:
- General Purpose
- Protect Feature:
- Sealed
- Size:
- Subminiature
- Theory:
- Time Relay
- Contact Load:
- Low Power
- Contact Form:
- Conversion type
Packaging Details
- Unit Type:
- piece
- Package Weight:
- 0.150kg (0.33lb.)
- Package Size:
- 15cm x 10cm x 5cm (5.91in x 3.94in x 1.97in)
A variety of modes in one:
P-1: Time relay (0.1 seconds to 99.9 seconds timing)
P-2: The relay (1 to 999 seconds or 1 to 999 minutes timing)
P-3: Counting control relay
P-4: voltage detection control relay
P-5: switch timer trigger (when the input level switch or timer to set the trigger value)
P-6: LED display Auto off setting (minimum operating current 6mA / 12V)
Default shipping is 12V version, the power supply DC10 ~ 16V
5V power supply required version pleaseitem.taobao.com/item.htm?id=13331193647.
Please read the instructions before using the wiring operation again!
Download the electronic version:pan.baidu.com/s/1ntA1ZWP
English version Description:pan.baidu.com/s/1gdy2X7H
Timing range: 0.1 to 99.9 seconds, 1-999 seconds or 1-999 divided into three groups (through key settings).
Voltmeter display range:Default0-99.9V (precision 0.1V)
Relay parameters:
Coil Input DC5V / 12V (corresponding to the power supply for the DC 5V version / DC 12V version)
A set of conversion (normally open normally closed)
Contact load: 10A / 277VAC
Contact resistance: ≤100mΩ (1A-6VDC)
Mechanical durability:> 10 million times
Electric Durability:> 100,000 times (10A-250VAC)
Working temperature: -40 ~ 85
External signal input: voltage (5-26V) or no voltage switching (can be set to 9 debounce delay time)
Parameter settings can be powered down to save
Standby current: 16mA / 12V, digital closedMinimum 6mA / 12VAnd relay timely 45mA / 12V
If power is lost in either mode operation, the system will continue to power again after the last state to run off the set parameters can be saved in either mode, press ENTER key for 3 seconds to return to the mode selected.
P-1, P-2, P-3 mode, used as a timing relay, time relay, count relay application video :( control 220V AC light bulb)
http: // tudou.com/programs/view/tSX091IGb3I/
P-4 mode as a voltage relay demo video:
tudou.com/programs/view/yXPVSZ-X2bQ/
tudou.com/programs/view/D7zAOiEjvZI/
P-5 mode, the switch trigger chronograph function demo video:
tudou.com/programs/view/y6PJVrgwhcg/
P-1: time relay mode
Timing range: 0.1 to 99.9 seconds; the timer can be set two timer value T1 (pull time), T2 (release time), you can execute an infinite loop or a single countdown to execution.
P-2: Time relay mode
Timing range: 1-999 1-999 seconds or minutes, can be selected via the button; the timer can be set two timer value T1 (pull time), T2 (release time), you can execute an infinite loop or a single countdown to execution.
Loop execution:
The relay mode (P-2), the user can set the relay pull-time T1 and release time T2, T1 is set to three seconds for example, T2 is seven seconds, then relay run will first perform three seconds and then pull released for 7 seconds, and so on.
When you set the T1 and T2 time, the system can be powered down to save, T1 is automatically loaded the next time after power relay T2 T1 time before release time.
Single execution timing:
If only set T1 (pull time), T2 (release time) is 0, the relay is timed run after T1 time to stop, no cycle operation, this time can be used as a timer, T1 time time to complete, the relay is released, Press ENTER key at this time, the system will re-start timer to T1 time.
If T1 (pull time) is set to 0, the relay has been in a released state (does not start running normally closed connected to the normally open points off).
By external digital / pulse inputs can control the start and stop time of the relay. In regular operation, the external switch input will not affect the regular operation, to be determined at the end, it will start again when the timer has an external switch signal input.
Timing relay needs a trigger to start rising switching signal or external pulse signal (no voltage switch is turned on, or voltage signal from low to high), if the input level remains unchanged (or switch does not act ), does not trigger starts the timer.
P-3: Counting relay mode
Can be used for external pulse or digital counterThe maximum value is 3999, and set the nine external signal debounce delay value, the maximum count frequency 1M, the count signal is connected to the chart on the right switch signal input terminal.The input signal can be switched (active or passive switch pulse) by shorting cap, external proximity switches, switches and other sensors, proximity switches can be used three-wire PNP normally open type, with no need to switch shorting cap PNP proximity switch input,The proximity switch normally open output relay board line access switch / pulse to the positive input terminal (IN +),Input voltage should be within the range 5-26V.
Due to mechanical switch contacts will have jitter may cause malfunction count, in order to avoid erroneous switch jitter, press the ENTER key to select the input pulse to shake level can be set to 9, 10ms latency increases each level, display "DL0 "not to delay," DL9 "to delay 90ms.
Counting mode can be set so that the count value of the relay, when the external input count reaches the set value, the count value is automatically cleared weight, relay parameters press "P-2 relay mode" setting executionThe minimum time is one second timer (For 0.1 seconds minimum precision timing may remark message).For example, at the time you set timing relay mode released after 2 seconds, then count to the set value, the relay will pull two seconds and then release, if time relay parameters are set0When the count reaches setpoint relay status will switch (release change pull, pull change released).
P-4: Voltage RelayMode
Voltage detection control function can be set on the lower voltage limit, the relay contact voltage exceeds the upper limit by the release changePullUntil the voltage is below the lower limit set only released again, this function can be used for voltage monitoring temperature, and control the use of other sensors can also be used as a DC voltage, voltmeter display range:The default is0-99.9V, error ± 0.1V.
This mode can be set to control the voltage detection upper limit and lower limit voltage correction value (-0.5 ~ + 0.5V.
Voltage detection control mode demo video:
tudou.com/programs/view/yXPVSZ-X2bQ/
The factory default setting is the voltage exceeds the upper limit relay, the relay release voltage is below the lower limit, if the load connected to the relay normally open and common point, then turned on the load voltage exceeds the upper limit below the lower limit of the load is disconnected, If you want more than the upper limit voltage relays disconnect the load, then you may select one kind of the following two ways to achieve:
A: The load connected to the normally closed relay and the common point, see the wiring diagram, so that relay the detected voltage exceeds the upper limit pull, normally closed will be disconnected, the detection voltage is lower than the lower limit of the relay releases, often off point will be connected;
B: Long press the SET button for three seconds and release it at P-4 mode, the relay state is negated, the detected voltage exceeds the upper limit of the relay release, the detection voltage is lower than the lower limit relay.
Application examples:
Battery over-voltage and low voltage alarm control, automotive low-voltage detection and control, 12V battery discharge (by detecting the battery voltage (10.5-14V), control relay series power cement resistors, enabling the battery automatic discharge function).
P-5: switch timer trigger
You can switch or external input level timing (tap quantity / pulse input terminal"IN"), Start a timer or relay switching timing of the set value. Timing time at P-2 mode T1, T2 for the same group, 1-999 seconds or minutes adjustable.
If the external switch (also using a three-wire PNP normally open proximity switch) remains closed or remained level over the set value T1, the countdown effective, if less than the set value of the external switch timer T1 is disconnected, the countdown stops wait to start again. For example: you set up to 5 seconds T1, T2 2 seconds, the external switch is pressed for 5 seconds, the relay will pull two seconds and then turned off, or the relay does not pull. If set to 5 seconds T1, T2 is 0, the external switch is pressed for 5 seconds, the relay becomes energized, the external switch is pressed 5 seconds again, the relay changes to released.
Switch timer trigger function demo video:
tudou.com/programs/view/y6PJVrgwhcg/
P-6: digital closed automatically set
P-6 model is used to set the digital auto-off time (from 0 to 9 minutes, 0 is always on) to reduce the controller power turned off when the digital minimum standby current of 6mA / 12V. Each mode can be running off at the digital display only the close, the relay will not be affected.
Relay wiring section marked electrical safety warnings and slotted electrically isolated, high-current wire soldering process increase.